Try Before You Buy

Download a free sample of any of our exam questions and answers

  • 24/7 customer support, Secure shopping site
  • Free One year updates to match real exam scenarios
  • If you failed your exam after buying our products we will refund the full amount back to you.

2021 Valid NS0-173 test answers & Network Appliance Exam PDF [Q32-Q52]

Share

2021 Valid NS0-173  test answers & Network Appliance Exam PDF

Free Network Appliance NS0-173 Exam Questions & Answer from Training Expert DumpTorrent


Network Appliance NS0-173 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Storage Hardware components, Configuration, High availability, SAN Boot
Topic 2
  • Networking Hardware components, Configuration, High availability, SAN Boot
Topic 3
  • Compute Hardware components, Configuration, High availability, SAN Boot, UCS Manager
Topic 4
  • Virtualization Hypervisor Solutions, SAN Boot

NEW QUESTION 32
A client has a requirement to set up a FlexPod Datacenter with the NetApp fabric MetroCluster architecture. You want to enable connectivity between the deployments.
In this design, which two components are required to accomplish this task? (Choose two.)

  • A. Cisco Nexus 9000 switches
  • B. Cisco Nexus 3000 switches
  • C. Cisco Nexus 7000 switches
  • D. Cisco MDS 9300 switches

Answer: A,C

 

NEW QUESTION 33
A customer is configuring the UCS to handle a multitenant environment. The customer has created an organization within UCS for each tenant and would like to allow access to these organizations for only users that belong to that tenant.
In this scenario, which feature in UCS Manager should the customer use to accomplish this task?

  • A. Trusted Platform Module
  • B. User Roles
  • C. Locales
  • D. Service Profile

Answer: D

 

NEW QUESTION 34
Your customer wants assurances that all aspects of FlexPod are highly available.
Which statement is correct in this scenario?

  • A. Cisco UCS Manager maintains a replica of configuration information.
  • B. Cisco UCS Manager automatically copies its configuration data to a remote data store.
  • C. Cisco UCS Manager uses active-active architecture.
  • D. Cisco UCS Manager contains multiple UCS domains.

Answer: A

Explanation:
The management and data plane of Cisco UCS is designed for high availability and redundant access layer fabric interconnects. In addition, Cisco UCS supports existing high availability and disaster recovery solutions for the data center, such as data replication and application-level clustering technologies.

 

NEW QUESTION 35
Which port type would you configure when you connect a chassis to the Cisco Fabric Interconnects?

  • A. server ports
  • B. Ethernet uplink ports
  • C. FC storage ports
  • D. appliance ports

Answer: C

 

NEW QUESTION 36
A customer is using a FlexPod implementation that has 10 Gbps uplinks from the B-Series chassis to the fabric interconnect. The customer wants to upgrade the links to 40 Gbps.
In this scenario, which model of Cisco UCS server IOM is required?

  • A. 0
  • B. 2204XP.
  • C. 2208XP
  • D. 1

Answer: B

Explanation:
The Cisco UCS 2204XP Fabric Extender (Figure 7) has four 10 Gigabit Ethernet, FCoE-capable, SFP+ ports that connect the blade chassis to the fabric interconnect.

 

NEW QUESTION 37
A customer wants to deploy a performance-sensitive workload while leveraging NetApp Snapshot technology and technologies such as NAS and SAN.
Which architecture satisfies these requirements?

  • A. NetApp SolidFire
  • B. NetApp EF-Series
  • C. NetApp StorageGRID
  • D. NetApp AFF

Answer: A

 

NEW QUESTION 38
A client has a FlexPod Datacenter solution with four active fabric links in port channel mode established between the Cisco Fabric Interconnects and the IOMs on a Cisco 5108 blade chassis. The blade chassis is fully populated with Cisco UCS B200M5 blades. A worker in the data center inadvertently unplugs the fourth uplink cable from IOM-A while working in the rack.
In this scenario, what happens to the network traffic?

  • A. Connectivity for servers 3, 4, 7, and 8 all fail over to IOM-B.
  • B. There is a loss of connectivity for servers 4 and 8.
  • C. Traffic is load-balanced within IOM-A.
  • D. Traffic is load-balanced within IOM-B.

Answer: A

 

NEW QUESTION 39
A customer is evaluating management tools for a new FlexPod infrastructure. They desire a tool that can orchestrate the provisioning of UCS compute nodes, NetApp storage, and VMware networking.
Which tool satisfies the requirements of this customer's heterogeneous environment?

  • A. NetApp OnCommand Insight
  • B. UCS Central
  • C. UCS Director
  • D. NetApp OnCommand Unified Manager

Answer: C

 

NEW QUESTION 40
Which command would a FlexPod administrator use to determine whether an FC initiator has logged on to the fabric?

  • A. MDS9148>show fcfwd
  • B. MDS9148>show fcc
  • C. MDS9148>show fcdomain
  • D. MDS9148>show flogi database

Answer: D

 

NEW QUESTION 41
Click the Exhibit button.

A customer wants to ensure that FlexPod Datacenter connections to the storage layer are highly available. Which two configurations shown in the exhibit satisfy the customer's requirements? (Choose two.)

  • A. I.
  • B. IV
  • C. II.
  • D. III.

Answer: B,D

 

NEW QUESTION 42
An architect is designing a FlexPod environment with Cisco Nexus 5000 switches to SAN boot all of the ESXi hosts over FC.
In this scenario, what should the LUN ID number be?

  • A. LUN 3
  • B. LUN 0
  • C. LUN 1
    Section: (none)
    Explanation
  • D. LUN 2

Answer: B

 

NEW QUESTION 43
A customer wants to configure SAN boot for its FlexPod system. The customer must consider the minimum number of FC ports to be configured on each node in the ONTAP storage solution.
In this scenario, what is the minimum number of FC ports that should be configured per storage node?

  • A. one
  • B. two
  • C. three
  • D. four

Answer: C

 

NEW QUESTION 44
A customer is designing a FlexPod Datacenter with Cisco UCS C-Series servers. They intend to manage the solution with Cisco UCS Manager. They want to cable the servers to the Cisco UCS Fabric Interconnects.
In this scenario, which three configurations are supported? (Choose three.)

  • A. Multipath mode
  • B. DualWire Management mode
  • C. Cluster mode
  • D. SingleConnect mode
  • E. Direct Connect mode

Answer: B,D,E

Explanation:
Dual-wire Management (Shared LOM): Shared LAN on Motherboard (LOM) ports on the rack server are used exclusively for carrying management traffic. A separate cable connected to one of the ports on the PCIe card carries the data traffic. Using two separate cables for managing data traffic and management traffic is also referred to as dual-wire management.
SingleConnect (Sideband): Using Network Controller Sideband Interface (NC-SI), the Cisco VIC card connects one cable that can carry both data traffic and management traffic. This feature is referred to as SingleConnect.
Direct Connect Mode: Cisco UCS Manager supports an option to connect the Cisco UCS C-Series Rack- Mount Server directly to the FIs. This option enables Cisco UCS Manager to manage the Cisco UCS C- Series Rack-Mount Servers using a single cable for both management traffic and data traffic. The Cisco UCS VIC connects to the FI of the system. This connection uses a single connection from each VIC to each FI.
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/c-series_integration/ucsm4-0/b_C-Series- Integration_UCSM4-0/b_C-Series-Integration_UCSM4-0_chapter_01.html

 

NEW QUESTION 45
A customer has deployed a FlexPod Datacenter with Red Hat Enterprise Linux OpenStack Platform. The Cinder storage volumes that are attached to the Nova instances are not available.
Based on the terms of the cooperative support model, which three companies would the customer use to open a support case? (Choose three.)

  • A. Red Hat
  • B. NetApp
  • C. Microsoft
  • D. Cisco
  • E. VMware

Answer: A,B,D

 

NEW QUESTION 46
A FlexPod administrator is building a WWN pool for a server that has 33 ports.
In this scenario, what is the smallest size possible for the pool?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

 

NEW QUESTION 47
A customer wants to deploy a FlexPod solution that involves directly connecting the NetApp AFF storage using the FCoE protocol to the Cisco UCS Fabric Interconnects.
In this scenario, which Cisco UCS Fibre Channel mode would be used to accomplish this task?

  • A. access mode
  • B. trunk mode
  • C. end host mode
  • D. switching mode

Answer: D

 

NEW QUESTION 48
A customer has verified physical connectivity on the FlexPod. However, the LUNs are not available on the Cisco UCS server. To make the LUNs visible to the UCS, the customer must enable a switching feature for zoning.
In this scenario, what should the customer do?

  • A. Enable the device connector feature in Cisco UCS Manager.
  • B. Enable Spine mode on all the Cisco Nexus 9000 switches.
  • C. Enable NPV on all switches.
  • D. Enable NPIV on all switches.

Answer: A

 

NEW QUESTION 49
Click the Exhibit button.

The total number of servers that a Cisco UCS Mini chassis supports is set to a maximum of how many hosts as shown in the exhibit?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

 

NEW QUESTION 50
You are a data center architect at a service provider. You need to configure a new multi-tenant FlexPod service offering.
Which three UCS Manager features will you need to accomplish this task? (Choose three.)

  • A. service profiles
  • B. virtualization support
  • C. auto discovery
  • D. role-based access control
  • E. policies

Answer: A,D,E

 

NEW QUESTION 51
Which Cisco Nexus series switch supports NX-OS standalone mode or Application Centric Infrastructure (ACI) fabric mode?

  • A. Nexus 9000
  • B. Nexus 3000
  • C. Nexus 7000
  • D. Nexus 5000

Answer: A

 

NEW QUESTION 52
......

Top Network Appliance NS0-173 Courses Online: https://www.dumptorrent.com/NS0-173-braindumps-torrent.html