Try Before You Buy

Download a free sample of any of our exam questions and answers

  • 24/7 customer support, Secure shopping site
  • Free One year updates to match real exam scenarios
  • If you failed your exam after buying our products we will refund the full amount back to you.

Get Latest Oct-2021 Conduct effective penetration tests using DumpTorrent NS0-592 exam [Q17-Q35]

Share

Get Latest [Oct-2021] Conduct effective penetration tests using  DumpTorrent NS0-592

Penetration testers simulate NS0-592 exam PDF

NEW QUESTION 17
After you replaced the motherboard, the node stopped in the "waiting for the cluster application to come online" state.
Which two actions should you perform to troubleshoot this problem? (Choose two.)

  • A. Check the status of the cluster with the cluster ring show command.
  • B. Check the status of the HA with the interconnect-up field of storage failover show command.
  • C. Verify the setting of the cluster interconnect switch.
  • D. Verify that the physical links on the cluster ports are up.

Answer: A,B

 

NEW QUESTION 18
A new cluster running ONTAP 9.5 has just been installed and you want to create a FlexGroup volume. Which action will accomplish this task?

  • A. Use the storage pool create command.
  • B. Use the volume size command.
  • C. Use the Deploy utility to provision the FlexGroup volume.
  • D. Use the volume create command.

Answer: A

 

NEW QUESTION 19
Click the exhibit button.

A customer reports that storage latency has recently increased substantially. No changes have been introduced, and the traffic did not change.
Referring to the output shown in the exhibit, which corrective step should be taken?

  • A. Move some volumes off the affected aggregate.
  • B. Perform the volume reallocation.
  • C. Throttle the client traffic.
  • D. Add more spindles.

Answer: C

 

NEW QUESTION 20
A customer reports that a LUN is offline because the volume is out of space even though the space-reserve parameter is configured to enabled on the LUN.
Which two statements are correct in this scenario? (Choose two.)

  • A. Deduplication is inflating the LUN when it is brought online.
  • B. The volume has snapshots.
  • C. The containing aggregate is thin-provisioned.
  • D. The fractional reserve is set to 0%.

Answer: B,C

 

NEW QUESTION 21
Your customer has initiated several volume move commands to redistribute the workload in their 8-node cluster. To verify that this process is not affecting their client access, they were monitoring the network switches that provide client access, but they do not see the network load of the volume move command.
In this scenario, what is the reason for the behavior?

  • A. The volume move command uses copy offload protocol, so it does not show up when monitored.
  • B. The volume move command uses the intercluster LIFs, not the data LIFs.
  • C. The volume move command uses the HA iWarp interconnect, not the client access switches.
  • D. The volume move command uses the cluster interconnect switches, not the client access switches.

Answer: A

 

NEW QUESTION 22
Click the exhibit button.


Many end users are complaining that logging in their systems takes a long time. When the login to the desktop finishes, everything is fine. The home directories are on NetApp storage. You do not see any significant disk or CPU contention on the controller, so you gather output statistics from the controller and focus on SMB.
Referring to the exhibit, which two actions would help diagnose the problem? (Choose two.)

  • A. Collect more statistics to determine whether the controller itself is causing latency.
  • B. Engage your network team to make sure that there are no issues between the storage controller and the domain controller.
  • C. Engage your Windows team to make sure that the domain controllers are not overloaded.
  • D. Engage your desktop team to collect network traces from the clients.

Answer: A,B

 

NEW QUESTION 23
You migrated from a FAS3250 system to a new A200 system. After the migration, you notice that data compaction fails to be enabled on the migrated volumes.
In this scenario, which statement is correct?

  • A. You need to schedule background deduplication on all volumes.
  • B. The volumes are thick-provisioned.
  • C. You need a license to have full efficiency on AFF systems.
  • D. Data compaction is not supported on the A200 system.

Answer: B

 

NEW QUESTION 24
Your customer added a new DS2246 shelf to an existing stack on their FAS8060A system. The customer then noticed that the new shelf's disks appear with the shelf serial number instead of the shelf ID in the sysconfig -r command output.
What is the reason for this problem?

  • A. The ACP is cabled incorrectly.
  • B. The SAS is cabled incorrectly.
  • C. The new shelf has the same ID as another shelf.
  • D. There is failed IOM module in the new shelf.

Answer: B

 

NEW QUESTION 25
A customer called you after a failure in their Microsoft Hyper-V environment on the "SVM1" SVM. The customer wants to enable nondisruptive operations (NDO) to prevent future failures.
In this scenario, which two actions must be performed? (Choose two.)

  • A. Verify that the continuously-available option is set on the CIFS share.
  • B. Verify that the branchcache option is set on the CIFS share.
  • C. Verify that SMB3 is enabled.
  • D. Verify that SMB2 is enabled.

Answer: A,D

 

NEW QUESTION 26
Click the exhibit button.

You have just cabled a new shelf to a FAS8200. Running the system node run -node * sysconfig - a command indicates that multipath HA is configured. However, after running Config Advisor, you receive an error that your cabling is incorrect.
As indicated in the exhibit, which two actions will correct the cabling? (Choose two.)

  • A. Move the 0b SAS connection on the bottom controller to 0d on the bottom controller.
  • B. Move the 0b SAS connection on the top controller to 0d on the bottom controller.
  • C. Move the 0b SAS connection on the top controller to 0d on the top controller.
  • D. Move the 0b SAS connection on the bottom controller to 0d on the top controller.

Answer: A,C

 

NEW QUESTION 27
What is a major difference between NFSv3 and NFSv4.x?

  • A. NFSv4.x is stateless, and NFSv3 is stateful.
  • B. NFSv4.x is stateful, and NFSv3 is stateless.
  • C. NFSv4.x requires an auxiliary protocol for status monitoring, and NFSv3 does not.
  • D. NFSv4.x requires an auxiliary protocol for mounting, and NFSv3 does not.

Answer: B

 

NEW QUESTION 28
You configured iSCSI multipathing on a Windows host to a 2-node ONTAP cluster so that you can attach to some LUNs. You see that the host logging in to both iSCSI LIFs in the ONTAP cluster, and you notice that the igroup is correctly set. After you open Disk Management and rescan for disks, the NetApp LUNs do not show up.
In this scenario, what should be performed to enable the LUNs to be visible to the Windows host?

  • A. Configure the ONTAP nodes for HA and try scanning again.
  • B. Configure the SVM for FCP and try scanning again.
  • C. Set up LUN mapping and try scanning again.
  • D. Set up Selective LUN Mapping (SLM) and try scanning again.

Answer: D

 

NEW QUESTION 29
A customer reports that copying data over iSCSI attached LUNs is taking significantly longer than usual. The customer asks you to help to identify the root cause of this problem.
Which two perfstat sections would you use to accomplish this task? (Choose two.)

  • A. lun stats -vserver
  • B. statit
  • C. stats lun
  • D. stats volume

Answer: A,B

 

NEW QUESTION 30
Click the exhibit button.

A customer is reporting that numbers in the statistics volume show command output appear to be incorrect.
Referring to the exhibit, which statement is correct?

  • A. The problem is due to a difference in operation size.
  • B. There are operation types that are not listed in the output.
  • C. A case with NetApp should be raised to find the root cause.
  • D. Perfstat should be used to explain the behavior.

Answer: A

 

NEW QUESTION 31
A non-maskable interrupt event occurs. The system panics and then reboots.
In this scenario, what would have caused the panic?

  • A. a secd process
  • B. a volume location distributed database
  • C. an ICMP blackhole detector
  • D. a watchdog timer

Answer: D

 

NEW QUESTION 32
A customer has requested your assistance with replacing a DS224C disk shelf from their cluster nondisruptively.
Which two actions should be performed before physically replacing the shelf? (Choose two.)

  • A. Zero the disks before performing the physical shelf removal.
  • B. Upgrade the IOMs in the shelf before starting the removal process.
  • C. Verify that the system is configured as multipath high availability.
  • D. Verify that the drives in the shelves are spares and ownership is removed.

Answer: C,D

 

NEW QUESTION 33
An administrator wants to keep an automatic daily up-to-date copy of a volume at a disaster recovery location.
What should the administrator do to achieve this goal?

  • A. Configure a SnapMirror relationship to the remote location.
  • B. Perform a volume relocation to the remote location.
  • C. Configure a SyncMirror relationship to the remote location.
  • D. Perform an NDMP dump to the remote location.

Answer: A

 

NEW QUESTION 34
Click the exhibit button.

You execute a few commands and many fail, as shown in the exhibit.
What could cause the error?

  • A. The mgwd user space process on cluster1-02 failed.
  • B. The cluster-02 node is down.
  • C. The bcomd user space process on cluster1-02 failed.
  • D. The aggregates were manually brought offline.

Answer: B

 

NEW QUESTION 35
......

Tested Material Used To NS0-592 Test Engine: https://www.dumptorrent.com/NS0-592-braindumps-torrent.html